TECHNICAL SPECIFICATION
MODEL
900 VA
1100 VA
1600 VA
2100 VA
NOMINAL BATTERY VOLTAGE
12 VDC
24 VDC
SOLAR PANEL CONNECTED FOR 50AMPS PWM CHARGE CONTROLLER (MAX.)
850 Wp
850 Wp
1700 Wp
1700 Wp
AC MAINS MODE
INPUT VOLTAGE RANGE (NORMAL MODE)
100 to 290 VAC ± 5 VAC (Wide Range)
INPUT VOLTAGE RANGE (UPS MODE)
100 to 290 VAC ± 5 VAC (Wide Range)
CHANGEOVER TIME MAXIMUM
< 30 ms (in Normal Mode) and < 10 ms (in UPS Mode)
MAX. CHARGING CURRENT
5A to 18A ± 1A (User Programmable)
BOOST CHARGING VOLTAGE
14 VDC to 15 VDC ± 0.2 VDC per Battery (User Programmable)
BOOST CHARGING VOLTAGE (FACTORY DEFAULT)
14.4 ± 0.2 VDC for Tubular 13.8 ± 0.2 VDC for SMF
28.8 ± 0.4 VDC for Tubular 27.6 ± 0.2 VDC for SMF
LOAT CHARGING VOLTAGE (FACTORY DEFAULT)
13.7 ± 0.2 VDC for Tubular 13.5 ± 0.2 VDC for SMF
27.4 ± 0.4 VDC for Tubular 27.0 ± 0.2 VDC for SMF
BATTERY BACKUP MODE
OUTPUT VOLTAGE AT NO LOAD
220 VAC ± 7 VAC
OUTPUT FREQUENCY
50.0Hz ± 0.5Hz
OUTPUT WAVE FORM (AT NO LOAD)
100% Pure Sine Wave
BATTERY LOW ALARM
10.6 ± 0.2 VDC
21.2 ± 0.2 VDC
BATTERY LOW PROTECTION
10.4 ± 0.2 VDC
20.8 ± 0.2 VDC
OVERLOAD (NORMAL/UPS)
120% (30 Sec)
SHORT CIRCUIT (NORMAL/UPS)
300%
CHARGING MODE
MAX. CHARGING CURRENT
5A to 30Amp. ± 1.5Amp. (User Programmable
CHARGE CONTROLLER EFFICIENCY
> 98%
DESCRIPTION OF SWITCHES ON FRONT PANEL
S.NO.
SWITCH
FUNCTION(S)
SWITCH LED STATUS
1.
POWER
ON/OFF the UPS Output
System ON - Led ON
System OFF - Led ON
2.
INV/UPS
When it is Short Pressed it Enables UPS/Inverter Mode Selection
When it is Long Pressed Enables the UPS Parameter Setting :
The LCD Displays : “Edit Parameters Setting”
The Switches function now Change to :
POWER - Enter/OK Switch
INV/UPS - Increment Value
SMF/TUB - Decrement Value
HYBRID/PCU - Back/Exit Switch
UPS Mode ON - Led ON
UPS Mode OFF - Led OFF
3.
SMF/TUB
When it is Short Pressed it Enables TUBULAR or SMF Battery Selection
System ON - Led ON
System OFF - Led ON
4.
HYBRID/PCU
When it Short Pressed it Enables the Hybrid PCU Mode Selection
PCU Mode - Led ON
Hybrid Mode - Led OFF
DESCRIPTION OF CENTER LED ON FRONT PANEL
S.NO.
LED
DESCRIPTION
1.
GREEN
LED ON - Full Solar Used
LED Blinking - Partial Solar Used
LED OFF - No Solar Used
2.
RED
LED ON - PV Reverse Protection
LED OFF - No Protection Selected
CONVENIENCE