logo (1)_page-0001

home ups inverter

TECHNICAL SPECIFICATION
MODEL
900 VA
1100 VA
1600 VA
2100 VA
NOMINAL BATTERY VOLTAGE
12 VDC
24 VDC
AC MAINS MODE
INPUT VOLTAGE RANGE (NORMAL MODE)
100 to 290 VAC ± 5 VAC (Wide Range)
INPUT VOLTAGE RANGE (UPS MODE)
100 to 290 VAC ± 5 VAC (Wide Range)
CHANGEOVER TIME MAXIMUM
< 30 ms (in Normal Mode) and < 10 ms (in UPS Mode)
MAX. CHARGING CURRENT
5A to 18A ± 1A (User Programmable)
BOOST CHARGING VOLTAGE
14 VDC to 15 VDC ± 0.2 VDC per Battery (User Programmable)
BOOST CHARGING VOLTAGE (FACTORY DEFAULT)
14.4 ± 0.2 VDC for Tubular 13.8 ± 0.2 VDC for SMF
28.8 ± 0.4 VDC for Tubular 27.6 ± 0.2 VDC for SMF
LOAT CHARGING VOLTAGE (FACTORY DEFAULT)
13.7 ± 0.2 VDC for Tubular 13.5 ± 0.2 VDC for SMF
27.4 ± 0.4 VDC for Tubular 27.0 ± 0.2 VDC for SMF
BATTERY BACKUP MODE
OUTPUT VOLTAGE AT NO LOAD
220 VAC ± 7 VAC
OUTPUT FREQUENCY
50.0Hz ± 0.5Hz
OUTPUT WAVE FORM (AT NO LOAD)
100% Pure Sine Wave
BATTERY LOW ALARM
10.6 ± 0.2 VDC
21.2 ± 0.2 VDC
BATTERY LOW PROTECTION
10.4 ± 0.2 VDC
20.8 ± 0.2 VDC
OVERLOAD (NORMAL/UPS)
120% (30 Sec)
SHORT CIRCUIT (NORMAL/UPS)
300%
DESCRIPTION OF SWITCHES ON FRONT PANEL
S.NO.
SWITCH
FUNCTION(S)
SWITCH LED STATUS
1.
POWER
ON/OFF the UPS Output
System ON - Led ON
System OFF - Led ON
2.
INV/UPS
When it is Short Pressed it Enables UPS/Inverter Mode Selection
When it is Long Pressed Enables the UPS Parameter Setting :
The LCD Displays : “Edit Parameters Setting”
The Switches function now Change to :
POWER - Enter/OK Switch
INV/UPS - Increment Value
SMF/TUB - Decrement Value
HYBRID/PCU - Back/Exit Switch
UPS Mode ON - Led ON
UPS Mode OFF - Led OFF
3.
SMF/TUB
When it is Short Pressed it Enables TUBULAR or SMF Battery Selection
System ON - Led ON
System OFF - Led ON
4.
HYBRID/PCU
When it Short Pressed it Enables the Hybrid PCU Mode Selection
PCU Mode - Led ON
Hybrid Mode - Led OFF
PROTECTION
Battery Voltage Low (3 Auto Retries), Over Load (6 Auto Retries), Battery Full Charge, Over Temperature, Short Circuit

SETTING PROCESS
  • Step 1 : Long press the INV/UPS Switch until LCD Display : “Edit Parameter Settings”
  • Step 2 : Press POWER Switch (Enter/OK in Setting Mode) then “MAX BATT VOLTAGE” Setting Screen will appear if TUBULAR Battery Selected else “BATT LOW CUT” Setting Screen appear
  • Step 3 : To Change the Maximum Battery Voltage Value press INV/UPS Switch (Increment Value in Setting Nlode) or SMF/TUB Switch (Decrement Value in Setting diode)
  • Step 4 : After Setting Nlaximum Battery Voltage Now press POWER Switch (Enter/OK in Setting Nlode) then “BATT LOW CUT” Setting screen will appears
  • Step 5 : To Change the Battery Low Cut Voltage Value press INV/UPS Switch (Increment Value in Setting Mode) or SMF/TUB Switch (Decrement Value in Setting diode)
  • Step 6 : After Setting Battery Low Cut Voltage Now press POWER Switch (Enter/OK in Setting Mode) then “MAX GRID CHG” Setting Screen will appear
  • Step 7 : To Change the Maximum Grid Charging Current Value press INV/UPS Switch (Increment Value in Setting Nlode) or SMF/TUB Switch (Decrement Value in Setting Mode)
  • Step 8 : To Change the Grid Reconnect Voltage Value press INV/UPS Switch (Increment Value in Setting Mode) or SNIF/TUB Switch (Decrement Value in Setting diode)
    • Highly efficient battery charging algorithm as a result you will get non-stop power
    • Advanced DSP technology with Arm Cortex controller for absolute and stable and 100% pure sine wave output
    • Indications for Mains ON, UPS ON, Battery Low, Charging/Discharging, Over Load, Short Circuit, Thermal Trip on LCD Display
    • User-Friendly LCD for the display of mode of operation and all parameters
    • DUAL DIODE OF WORKING : UPS AND NORMAL
      - UPS Mode : Fast switching, Input operating range from 180V to 260V
      - Normal Mode: Wide Input operating range from 100V to 290V
    • DUAL BATTERY CHARGING MODE : TUBULAR AND SIMF BATTERY MODE
      - Different Battery selection mode to enhance the battery life
    • Intelligent overload sensing circuitry with auto retries facility
    • Programmable thermal protection : cooling fan which operates as needed
    • High Power new generation MOSFET cable to handle high in-rush/ surge current
    • Resettable AC circuit breaker which reduce service calls.
    • Double stage MOSFET Over Current Protection by measuring Rds ON
    • Highest efficiency at lower cost
    • Pure Sine Wave Output with low Total Harmonic Distortion (THD)
    • High End ARM-Cortex based design of Solar Charge Controller for charging through Solar Power
    • Eco-Friendly operation
    • Electronic Over Current Charging Protection
    • No mechanical contact for charge controller
    • Designed for continuous reliable and robust operation
    • AC Plains Voltage
    • Battery Voltage
    • Faults Status
    • Overload
    • Low Battery
    • Inverter Status
    • Output Voltage
    • Charging Mode
    • Short Circuit
    • High Battery
    • O/P Load in% on Battery
    • Grid Charging Current
    • Mains Fuse Trip
    • Over Temp
    • Grid Over Load
    certified
    pure website_page-0001 (1)

    SOLAR BATTERY

    ORROFAST Solar Battery designed for OFF-GRID System, as name suggest Batteries are powered by solar energy. Electricity generated from Solar Panel and stored into your ORROFAST Solar Batteries. Usage of clean Energy power has been increased globally from last couple of decades. Main reason for success of Off-Grid Solar System is the efficiency of the batteries. .

    GET STARTED

    WhatsApp Image 2022-11-25 at 11.30.53 (1)

    TUBULAR BATTERIES

    All the Inverter Batteries may typically work the same but what make ORROFAST Batteries different in the league is Lighting Technology, Rich quality raw materials & highly skilled with knowledgeable workforce that helps to deliver maximum power for extended durations and have an appreciably longer life span.

    GET STARTED

    SMF Battery Updated

    SMF/VRLA BATTERIES (100AH-240AH)

    Sealed Maintenance Free Batteries also known as Valve regulated Lead Acid (VRLA) Batteries are flat plate batteries that don’t need topping-up. These batteries are more environment friendly as they don’t release any fumes or gases on a continuous basis.

    GET STARTED