CHARGING CHARACTERISTICS OF SOLAR BATTERIES
MODEL OF OPERATION
VOLTAGE SETTING PER MONO-BLOCK UNIT FOR AMBLENT TEMPERATURE 25-30°C
CURRENT SETTINGS
FLOAT VOLTAGE
BULK VOLTAGE
LOW VOLTAGE DISCONNECT
12V Mono-Block
13.7V ± 0.1V
14.5V ± 0.1V
14.5V ± 0.1V
6V Mono-Block
6.85V + 0.1V
7.25V ± 0.1V
5.55V ± 0.1V
Maximum - 20% of battery Ah capacity
Maximum - 0% of battery Ah capacity
TECHNICAL DATA
SOLAR BATTERIES(IS)
BATTERY TYPE
SPEC
CAPACITY
DIMENSIONS
CELL
WEIGHT WITH ACID + WATER
TERMINAL
ELECTROLYTE
BATTERY MODEL
10hr
5hr
L
W
H
TH
Layout
Kg
Volume Ltrs
ASTL 20
20 Ah
20
17
305
170
180
230
R
13.5
L-Type
6.4
ASTL 40
40 Ah
40
33
410
175
190
240
L
22.0
L-Type
9.6
ASTL 75
75 Ah
75
62
500
220
205
255
L 3
36.0
L-Type
15.3
ASTL 100
100 Ah
100
83
500
220
205
255
L 3
40.0
L-Type
17.0
ASTL 120
120 Ah
120
100
500
190
360
410
L
54.5
L-Type
21.0
ASTL 150
150 Ah
150
125
500
190
360
410
L
59.4
L-Type
19.8
ASTL 200
200 Ah
200
180
500
190
360
410
L
65.0
R-Type
21.0
ASTL 220
220 Ah
220
200
500
190
360
410
L
68.0
R-Type
22.5
ASTL 240
240 Ah
240
220
500
190
360
410
L
71.0
R-Type
23.2
ASTL 250
250Ah
230
250
500
190
360
410
L
75.0
R-Type
24.0
ASTL 270
270Ah
270
250
500
190
360
410
L
78.0
R-Type
24.0
TUBULAR TECHNOLOGY
ORROFAST Tubular Batteries have the spines or the positive plate support cast at high pressure (100 Bar) in imported HADI machine which ensures void free structure which ensures void free orientation and can protect the plate support from anodic corrosion. This in turn ensures higher reliability and longer life. ORROFAST Tubular plates are also cast with low antimony content which reduces the topping up frequency, making the battery low maintenance type. This also keeps the float charging current at a lower value, thus minimises the total energy requirement needed to keep the battery in charged condition during standby float application.